PG.DCS2 window wiper

MAIN DESCRIPTION

The straight line wiper PG.DCS2 has the electric motor equipped with an electronic speed regulator able to communicate with other devices via the CAN bus. It is suitable for low (24 Vdc) and high (110/220 Vac) voltages. The wiper PG.DCS2 is designed to ensure:

  • Two operation modes: continuous and intermitent running with the arm movement synchronized and maximum speed running for each wiper. The operating conditions are stabilized by the speed regulator in a wide range of voltages;
  • Compact motor unit size with specially designed electric box: it is possible remove a motor without interrupting the CAN bus communication;
  • Motor unit overheating electronic protection.

The wiper PG.DCS2 is also available with double arm (type PGD.DCS2). On request these systems can be equipped with spray nozzles (option PG.ZZ) and with heated frame (option PG.HOT).

Motore PG.DCS
WIPER HOUSING AND MOTOR

 

  • Available rated voltage: 24Vdc, 110Vac, 220Vac;
  • Superior components are used to ensure long lasting systems;
  • Automatic self-parking position.
PG_Solution
WIPER ARMS AND BLADES

 

  • Wiper arms lengths are designed to suit all applications;
  • Wiper arms springs pressures are carefully selected to ensure smooth operation;
  • All arms constructed out of non-corrosive materials such as stainless steel AISI 316;
  • Both the arm base and the blade can be rotated (blade rotation is optional) to fit the glass geometry;
  • Flat and articulated blades. Blade length is selected to suit all applications.
P_Control Systems
CONTROLLERS

 

  • DCS panel allows to operate up to 5 groups from 1 up to 8 wipers;
  • It is available in two sizes and different versions, depending on number and layout of the wipers;
  • Operating modes are available: intermitting mode, continuous mode;
  • The panel is backlighted, with dimmer;
  • The electrovalves for window washer equipment with a predetermined washing cycle;
  • Extensive customization for aux management.
UNZZ e NZZH PG
WASHING EQUIPMENTS AND ACCESSORIES

 

  • Electrovalves for water or purge air supply;
  • Wash hose kits with various adaptors for securing hoses;
  • Wall or wiper arm installed spray nozzles;
  • Fully integrated wash systems including controllers;
  • Windows custom made antiglear screens.

Motor Features

Model Number
PDCS2PG.DCS2 Straight line wiper motor
Power supply voltage V
V = 24 Vdc; 110/220 Vac

Housing Features

Wall Thickness DD = 18-35-70-105-150 mm
Wiper stroke length CC = 400÷2250, 50 mm steps for PG.DCS model
C = 900÷4500, 50 mm steps for PGD.DCS model
Motor Unit Side PositionMotor unit can be positioned above or below the window, on the right or on the left side.
Spray NozzlesAdjustable fan shape 0° or 90° are available for all models.

Heating ElementMechanism case heaters 110 Vac or 220 Vac are available.
Cable Length1.5 m as standard.

Other length on the request.
FinishingHousing finishing standard is polyester coating white RAL 9010.

Other finishes on the request.

Arm Features

Model Number
16721Arm length shorter than 450 mm
16720 Arm length longer than 450 mm
16723
Arm length shorter than 450 mm, adjustable blade fix
16722 Arm length longer than 450 mm, adjustable blade fix
Wiper Arm Length LL = 300÷1000 mm, 50 mm steps
BendingWiper arm may be cranked for inward glass window over 75 mm.

All solution customed.
FinishingStainless steel (as standard)

Other finishes on request

Blades Features

Model Number
BLFWiper blades for flat windows, for heavy duty applications
XWiper blades for curved windows, for heavy duty applications
Blade Length SS = 500 ÷ 1200 mm, with 50 mm steps,  1300, 1400, 1500 mm

Control Panel Features

Operation ModesOperation with panel: CAN bus commands is generated from a control panel, with a standard keypad proposed by us

Operation with gateway: CAN bus commands is generated from a gateway connected with switches installed by the customer on the consolle

Direct operation: CAN bus commands is generated directly from the integrated bridge system
Number of WipersAdvanced control allows to operate up to 12 groups from 1 up to 8 wipers.

It allows a perfect synchronization of the wipers in all operating conditions, both in continuous and intermittent operation mode. Synchronization occurs even if the wipers are different in dimensions and wiping angles.
Number of Auxiliariese DCS system provides the possibility to drive auxiliary devices that normally equips ship bridge, like elvalves of window rinse system, glass heater and wiper heater contactors and other devices. Each motor/control unit can manage 1/2 auxiliary. For centralized management of auxiliaries, we offer an auxiliary devices control unit, DCS.AUX4, a relay unit controlled by CANbus messages, which provides 4 power outputs to drive such auxiliaries.
Windscreen Wiper PG.DCS2 Brochure